Smart Smoke-Free Solution for Public Restrooms


Release time:

2024-05-10

Smart Smoke-Free Solution for Public Toilets

 

Public restrooms are an indispensable part of urban infrastructure; however, smoking often creates significant inconveniences and safety hazards in these facilities. To safeguard public health and enhance the environmental quality of public spaces, intelligent smoke‑free solutions have been developed.

We will introduce a method based on cigarette detection sensors, The smart smoke‑free solution integrating a LoRa communication gateway and an alarm control panel is designed to create a fresh, comfortable public restroom environment.

Cigarette detection sensor

Cigarette detection sensors are one of the key components of intelligent smoking‑cessation solutions. By installing these sensors in critical areas of public restrooms—such as entrances and designated smoking zones—they can continuously monitor airborne smoke concentrations in real time.

The sensor boasts high sensitivity and accuracy, enabling it to reliably detect smoke and promptly issue an alert.

 

Product image

           Cigarette detection sensor

Product Specifications

Specifications

Parameter

Particulate matter range

0-999ug/m3

Resolution

1ug/m3

Monitoring area

20 square meters

Alarm Mode

Voice broadcast /LoRa alarm upload

RS485 output

MODBUS protocol

 

Basic Parameters

Specifications

Parameter

Operating voltage

DC12V

Quiescent current

< 120mA

Alarm current

< 220mA

Operating temperature

-10℃~60℃

Operating humidity

5%~80%RH

Size

Diameter 120mm * 42mm

Weight

200g

Installation method

3M adhesive mounting, ceiling-mounted installation

 

 

LoRa communication gateway

The LoRa communication gateway is a critical device for transmitting data acquired by cigarette‑detection sensors to a remote server. LoRa technology offers long‑range transmission, low power consumption, and high reliability, making it well suited for large‑scale data‑transfer applications.

Through a LoRa communication gateway, smoke data collected by sensors can be transmitted to a remote server, enabling real-time monitoring of smoking activities in public restrooms.

 

Product image

     

         LoRa communication gateway

 

Product Specifications

Project

Parameter

 

Main control CPU

240 MHz clock speed

 

Data interface

1 Ethernet port, 1 RS485 interface

 

Network protocol

IP, TCP, UDP, HTTP, HTTPS

 

Internet of Things Protocol

Support MQTT

 

Wireless

Supports two channels LORA wireless communication, with a wireless frequency band of 470 MHz.

Default is one channel. The LORA wireless frequency band can be customized.

Wireless protocol

Support LoRa wireless protocol

 

Power supply method

DC power supply, voltage range 6V to 12V.

 

 

Alarm control panel

The alarm control panel is a key component of the intelligent smoking‑prevention solution, responsible for receiving and processing smoke data transmitted by sensors. Once it detects someone smoking in a public restroom, the alarm control panel will immediately sound an alert.

It also uses audio‑visual alerts to notify management personnel for appropriate action. Meanwhile, the alarm control panel can upload detailed information about smoking incidents to a cloud server for subsequent management and analysis.

 

Product image

 

             Alarm control panel

  • Product Specifications

Project

Parameter

Note

Main control CPU

Clock speed 2GHZ

Can be replaced with a带 A controller with 0.8 TFLOPS of computing power, but at a higher cost.

Storage

4G DDR3, 128G EMMC

 

Monitor size

10.1 inches

 

Resolution

1024X600

 

I/O input

Channel 12 DI input

This one Minimize the number of DI inputs; 16 channels is already quite a lot, otherwise achieving IP67 waterproofing becomes difficult.

I/O output

12-channel DO outputs; relay outputs can handle 220 V/0.5 A.

Do not use relay output at this location; the hole is too small, and it will not pass. A current of 220V/0.5A is a bit challenging.

AI data collection

Support Data acquisition for 2-wire 4–20 mA signals

 

RS485 interface

2-wire RS485

 

Communication interface

One LAN port and one WLAN port.

 

Status Display

The LED can indicate the status of each I/O channel. Status

 

Protection rating

IP67

 

Installation method

Wall-mounted installation

 

Operating system

Support LINUX

 

Software system

Support Web Interface Operations

 

Operating temperature

-20℃~80℃

Third-party reports can be issued, with costs ranging from… Around 10,000

Power supply method

220V power supply

Can you or not? Powered by a 24V supply, which makes achieving a higher waterproof rating easier.

 

 

Solution Advantages

Using a cigarette detection sensor, The smart smoke‑free solution featuring a LoRa communication gateway and an alarm control panel offers the following advantages:

 

Real-time monitoring: via sensors and The LoRa communication gateway enables real-time monitoring of smoking behavior in public restrooms, promptly detecting violations.

High reliability: LoRa technology offers stable and reliable data transmission, ensuring the accuracy and integrity of the data.

Efficient Alarm Reporting: The alarm control panel promptly and accurately detects smoking incidents and triggers an alert, notifying management to take timely action and prevent the spread of smoking behavior.

Environmental Improvement: Smoking has been effectively prohibited in public restrooms, leading to improved air quality and enhanced comfort in the public environment.

 

The implementation of intelligent smoking‑cessation solutions helps safeguard public health and enhance the environmental quality of public spaces. By integrating cigarette‑detection sensors, LoRa communication gateways and alarm control panels fully leverage modern technological solutions,

It enables intelligent monitoring of smoking behavior and timely alerts, providing crucial support for the management and maintenance of public restrooms.

MORE NEWS